EasyManuals Logo

Zte ZXR10 2952E User Manual

Zte ZXR10 2952E
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #245 background imageLoading...
Page #245 background image
Chapter5Management
10.CRCportdisplaymode(CRC):Inthismode,aportindicatordisplaystheCRCerrors.
IfthereisaCRCerrorframeontheport,theyellowindicatorislit.IfthereisnoCRC
errorframeontheport,theindicatorisnotlit.
11.STORMportdisplaymode(STORM):Inthismode,aportindicatorindicatesastorm
port.Iftheportisastormport,theyellowindicatorislit.Iftheportisnotastormport,
theindicatorisnotlit.
12.NoMACportdisplaymode(NoMAC):Inthismode,aportindicatorindicateswhethera
MACaddressislearnt.IftheportdoesnotlearnaMACaddress,theyellowindicator
islit.IftheportlearnsaMACaddress,theindicatorisnotlit.Thismodesupports
trunk.IfatrunkportlearnsaMACaddress,theindicatorsoftheactiveportsinthe
trunkarenotlit.
13.PoEmode:Inthismode,aportindicatorindicatesthePoEstatus.IfPoEisnormal,
thegreenindicatorislit.IfaPoEexceptionoccurs,theyellowindicatorislit.Ifthere
isnopower,theindicatorisnotlit.Only2910E-PSand2918E-PSsupportthismode.
M_ButtonFunctionModeSwitch
1.Thereisamodebuttononthepanel.Pressitonce,andthentheindicatorforthe
nextmode(thesequenceinwhichthemodesdescribedintheprevioustopic)begins
ashingfor2seconds.Ifthebuttonisnotpressedin2seconds,themodeindicatoris
off.Thedeviceentersthismodeandexecutesthefunctionofthismode.Ifthebutton
ispressedin2seconds,thedeviceentersthenextmode.Thenextmodeindicator
beginsashing.Thepreviousprocessisrepeated.
2.Inamode,ifthemodebuttonisnotpressedin3minutes,thedeviceexitsfromthis
modeautomaticallytotheLINKmode.Ifthebuttonispressed,thedeviceentersthe
nextmode.Thecorrespondingmodeindicatorbeginsashing,whichisasdescribed
in1.
3.InthePINGmode,apingpacketissentonceper20seconds.Inothermodes,the
statusesareupdatedinrealtime.
5.10Telnet
TelnetOverview
AsamemberoftheTCP/IPprotocolfamily,theT elnetprotocolisthestandardprotocolfor
theremoteInternetloginservice.Withthisprotocol,userscanperformoperationsona
remoteswitchthroughthelocalPC.
AZTEswitchcanbeusedasbothaT elnetclientandaT elnetserver.
TelnetConguration
Telnetcongurationincludes:
5-45
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2952E and is the answer not in the manual?

Zte ZXR10 2952E Specifications

General IconGeneral
ModelZXR10 2952E
CategorySwitch
Jumbo Frame9K
Weight4.5 kg
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Dimensions440 mm x 44 mm x 300 mm
Power SupplyAC 100-240V, 50/60Hz
VLAN4K VLAN
Operating Temperature0°C to 45°C