EasyManua.ls Logo

ZyXEL Communications GS2210 Series - Page 387

ZyXEL Communications GS2210 Series
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 44 Diagnostic
GS2210 Series User’s Guide
387
Cable length This displays the total length of the Ethernet cable that is connected to the port when the
Pair status is Ok and the Switch chipset supports this feature.
This shows N/A if the Pair status is Open or Short. Check the Distance to fault.
This shows Unsupported if the Switch chipset does not support to show the cable
length.
Distance to
fault
This displays the distance between the port and the location where the cable is open or
shorted.
This shows N/A if the Pair status is Ok.
This shows Unsupported if the Switch chipset does not support to show the distance.
Locator LED Enter a time interval (in minutes) and click Blink to show the actual location of the
Switch between several devices in a rack.
The default time interval is 30 minutes.
Click Stop to have the Switch terminate the blinking locater LED.
Table 194 Management > Diagnostic (continued)
LABEL DESCRIPTION

Table of Contents

Other manuals for ZyXEL Communications GS2210 Series

Related product manuals