Installation manual 2N® IP Force
•
1.
2.
3.
a.
b.
c.
4.
5.
6.
7.
a.
b.
c.
8.
9.
Tamper switch: 24 V / 50 mA AC/DC
Module mounting:
Switch off the intercom.
Remove the front panel from the intercom.
According to your model
If you are mounting the switch into a two-nameplate model, demount the button PCB (1)and remove
the right-hand bottom spacer (there are four PCB fitting spacers altogether).
If you are mounting the switch into a keypad model, take the keypad out of the holder.Demount the
right-hand keypad holder–beam with a pin (8) – remembering its position.Demount the right-hand
bottom spacer. Do not disconnect the keypad cable!
If you are mounting the switch into a model other than the two ones mentioned in items 3aand 3b
above, remove the right-hand bottom screw from the main board.
Now screw the enclosed 12 mm spacer (5) into the vacated main board slot.
Mount the enclosed plastic support (6) onto the switch board bottom side.
Put the switch board (4) in the main board connector making sure that the screw hole isdirectly above the
spacer.
According to your model
If you are mounting the switch into a two-nameplate model, fit the switch board with theenclosed
10.5 mm spacer (3) and reinstall the button PCB (1).
If you are mounting the switch into a keypad model, reinstall the beam (8) of the keypadholder (the
slot is on top). Insert the enclosed 4.5 mm washer (9) between the beam and theswitch board, fitting
the assembly with the 15 mm screw enclosed (7).
If you are mounting the switch into a model other than the two ones mentioned in items 7aand 7b, fit
the switch board with the original 6 mm screw (2).
If you want to use the tamper switch, insert the tamper board (9) in the connector locatedin the right-hand
bottom part of the switch board (4). As the tamper switch shares the relay output (NO and NC) terminals, you
cannot use theRELAY2 output with the tamper switch together.
Place front panel back and tighten all four screws.