Installation manual 2N® IP Force
90 / 118
The2N
®
Security Relay(Part No.9159010) is used for enhancing security
between the intercom and the connected electric lock.The2N
®
IP Security
Relayis designed for any2N IPintercom model withfirmware versions 1.15
and higher. It significantly enhances security of the connected electriclock
as it prevents lock opening by forced intercom tampering.
Function:
The2N
®
Security Relayis a device installed between an intercom (outside
the securedarea) and the electric lock (inside the secured area).
The2N
®
Security Relayincludesa relay that can only be activated if the
valid opening code is received from the intercom.
Specifications:
Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC
Switched output:
Where the security relay is fed from the intercom, 9 to 13 V DC is available on the output depending on the
power supply (PoE: 9 V; adapter: source voltage of minus 1 V) / 400 mA DC.
Where the security relay is fed from an external power supply, 12 V / 700 mA DC is available on the output.
Dimensions: (56 x 31 x 24) mm
Weight: 20 g
Installation:
Install the2N
®
Security Relayonto a two-wire cable between the intercom
and theelectric lock inside the area to be secured (typically behind the door).
The device is poweredand controlled via this two-wire cable and so can be