2N TELEKOMUNIKACE a.s., www.2n.cz 60/105
2.3.1 Overvoltage Protection
Recommendations for Additional Overvoltage Protection Installation
If running:
a) outside a building,
b) on/in an outer wall or roof,
the 2N device wiring may be exposed to atmospheric effects resulting in overvoltage
that may subsequently damage any devices installed outside the building, on its outer
wall or roof. Overvoltage may damage devices connected to these wires and installed
inside the building as well. Therefore, we recommend that additional surge protectors
be installed on all the wires leading outside buildings, on outer walls or roofs, namely:
a) as close as possible to the device installed outside the building or on its outer wall
/roof,
b) as close as possible to the point where the wires leave the building.
Examples of Overvoltage Protection Installation:

Questions and Answers:

Question and Answer IconNeed help?