14
4-SPECIFICATIONS
4.1 Power Requirements
Electrical: 115 VAC, 60 Hz, 6.4 A (675 watts)
Pneumatic: 85 PSIG [6 bar pressure], 2.5 SCFM
[70 liter/minute @ 2PC, 1.01 bar] maximum at maximum random cycle rate.
A pressure regulator/ lter is included
The machine is equipped with a 2.4m [8 foot] standard neoprene covered power cord and a grounded plug.
Contact your 3M Representative for power requirements not listed above.
4.2 Operating Rate
3M-Matic™ 7000r-7000r3 Pro random case sealers can process up to 24 different case sizes per minute.
IMPORTANT SAFEGUARD
4.5 Tape Width
50mm [2 inches] minimum to 72mm [3 inches] maximum
4.4 Tape
Scotch
®
pressure-sensitive lm box sealing tapes.
4.3 Operating Conditions
Use in dry, relatively clean environments at 4.4
o
C to 48.9
o
C [40
o
F to 120
o
F] with clean, dry boxes.
Note: Machine should not be washed or subjected to conditions causing moisture condensation on
components.
To reduce the risk associated with
fire and explosion hazards:
Do not operate this equipment
in potentially ammable/explosive
environments.
7000r-7000r3 Pro - NA
2014 June
WARNING