EasyManua.ls Logo

3M 3M-Matic 7000r - Bumper Supports; Box Size Capacity; Electrical Connection and Controls; Initial Start-Up

3M 3M-Matic 7000r
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
7-INSTALLATION AND SET-UP (continued)
7.12 Box Size Capacity of Case Sealer
At its factory setting, the case sealer handles a
variety of box sizes. If larger capacity is needed,
the machine can be adjusted to accommodate
larger boxes.
Refer to Specif cations Section.
Note - Machines outside the U.S. may be equipped
with 220/240 Volt, 50 Hz systems, or
other electrical requirements compatible
with local practice.
7.14 Initial Start-Up of Case Sealer
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
7.13 Electrical Connections and Controls
The electrical and pneumatic "On/Off" switch and
the Push Button Station "Start/Stop" are located on
the left side of the machine frame (Figure 7-13).
If desired, for operator convenience, the "On/
Off" and "Start/Stop" switches can be relocated to
the right side of the machine frame. A standard
three conductor power cord with plug is provided
at the back of the electrical control box for (See
Speci cations) electrical service. The receptacle
providing this service shall be properly grounded.
Before the power cord is plugged into outlet make
sure that all packaging materials and tools are
removed from the machine.
Do not plug electrical cord into outlet until ready
to run machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5mm diameter [AWG16],
have a maximum length of 30.5m [100 ft], and
must be properly grounded.
7.11 Bumper Supports (Upper Drive Assembly)
With the Safety Guard removed (Figure 7-12):
Also See Special Set-Up Procedure -
Column Bumper Installation
Raise and lock the upper drive assembly in the
raised position. See "Operation – Mechanical
Latch."
Turn off air supply and electric power.
Remove the Column Bumper and set screw parts
package from the carton.
Using set screws provided, install Column
Bumper (the recommended position is
shown below).
Re-install Safety Guard.
Important: Some bumper positions may:
1) Allow upper and lower taping heads to come into
contact with each other.
2) Create added stress to the bumper.
3) Cause a malfunction of the machine.
These events can potentially cause damage to the machine.
For more information on bumper settings, contact
your 3M service representative.
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot
and vehicle traf c.
To reduce the risk associated with
impact hazards:
Always use appropriate supporting
means when working under the upper
drive assembly
To reduce the risk associated with
mechanical and electrical hazards:
Allow only properly trained and
quali ed personnel to operate and/or
service this equipment
7000r-7000r3 Pro - NA
2014 June
WARNING
WARNING
Figure 7-12
(Shown is
after Safety
Guard is
Removed)

Table of Contents