General Set Up and Spray Gun Use cont.
Adjusting the Fan PatternSize
The fan size is regulated by the fan adjustment knob
as noted in Fig. 2. The spray gun in the kit is preset in
the closed position (gently turn the fan adjustment knob
clockwise to verify; knob should not move). Next, turn the
knob counter-clockwise 1.5 rotation. The fan adjustment
will allow you to spray from a small round to a full
fanpattern.
Fig. 2
Fan Adjustment
Knob
Vertical Pattern
Horizontal Pattern
Note: The spray pattern can also be changed from vertical
to horizontal by rotating the air cap a 1/4turn.
Do not point the spray gun up while cleaningit.
Do not immerse the spray gun insolvent.
Do not wipe the spray gun with a cloth soaked in solvent;
wring out theexcess.
Do not use metal tools to clean the air cap holes as this may
scratch them; scratches can distort the spraypattern.
Note: Do Not Put In Gun Washer. Read, understand and follow all safety statements as well as wear
appropriate, approved personal protective equipment per the applicable SDS and material container labels for
cleaningsolutions.
Periodically, lubricate moving components such as the fl uid needle, fan adjustment threads, uid needle adjustment threads
and spring.