20
4s3™ Semi-Automatic Sheet Heat Sealer
a4S Automatic Heat Sealer, Operation Manual V2.8
7 AppendixA:TechnicalSpecications
Parameter Specication
Mechanical Dimensions (H x D x W) 313 mm x 277mm x 181 mm
Weight 10 kg
Electrical Voltage 00-115/230 ±10% Vac
HT121TS_4B_en_d.doc Page 12 of 35
Frequency 50/60 Hz
Power at 100-115V 240-300 VA
Power at 230V 300 VA
Environmental Temperature range Operative 18°C - 35°C
Storage -20°C – 40°C
Relative humidity 20% - 80% not condensing
Maximum altitude 2000 m
Sound Pressure Level Maximum measured level 60 dbA (below the limits of 85 dbA dened by regulation in force)
Safety Information Pollution degree 2
Overvoltage category II
Devices for use indoors
Setup Parameters Sealing temperature: OFF or from 60°C to 200°C
Step: 1°C
Default: OFF
Sealing time: from 0.0 to 10 seconds
Step: 0.5 second
Default: 3 seconds
Stand by cycle: “no” stand-by or from 1 to 99 minutes
Step: 1 minutes
Default: 60 minutes
Stand by temperature: 60°C, not programmable
HT121TS_4B_en_d.doc Page 13 of 35
Power down temperature: ambient
Warning acoustic (Buzzer): ON/OFF
Default: ON