Table 1. Gas Pressure and Electrical Characteristics
*Manifold Pressure
Minimum
Supply Pressure
Maximum
Supply Pressure Electrical Characteristics
Gas Type In. W.C. (kPA) In. W.C.(kPA) In W.C.(kPA) Volts/Hz Amperes
Natural 0” (0) 3.5(1.10) 14(3.49) 120/60 <10
* The manifold pressure is the factory setting and is not adjustable. A negative pressure will be seen with just the blower