TroubleshootingGuide
18|Page
ERRORCODE721[510(T‐D2)],SIXFLASHES/72[110(T‐KJR2),310(T‐K4)]
FALSEFLAMEDETEC TION
1) Firstandforemost,shutoffallgasandpowertotheunit.Theproblemcouldbetheflamesensor,
butifitisn’t,thisisaverydangeroussituation.
2) ContacttheTechnicalServiceDepartmentforfurtherassistance.
ERRORCODE741[510(T‐D2)],74[110(T‐KJR2),310(T‐K4) ]
MAINREMOTECONTROLPROBLEM
Thiserrorcodeonlyoccurswhenthereisamiscommunicationbetweenthetemperatureremote
controllerandthewaterheater.
1) Checkthatallwiringisproperlyconnectedtotheremote.
2) Verifythecorrectmodelofremoteisbeingusedforthecorrespondingtanklessmodel.
3) Verifythatonlyaremote
isinstalled.Multipleremoteswillresultinthiserrorcode.
4) Ifyoudisconnecttheremotefromtheheaterwiththepowersupplyon,thiserrorcodewillresult.
Turnoffpowerbeforedisconnectingtheremotefromtheheater.
5) Checkforanysignsofpowersurges.
ERRORCODE761[510(T‐D2)]
COMMUNICATIONFAILURE
1) Thiserrorcodeonlyoccursinamultipleheatersetup,wherethereisamiscommunicationbetween
masterandslaveunitsforEasy‐Linksystems.
2) Thiserrorcodewillonlybedisplayedonthemasterheater.
3) Thiserrorindicatesthatthemasterunithaslostcommunicationwiththeindicated
heater.
4) Verifythatthereispowertotheunitthathaslostcommunication.
5) SeetheInstallationManualforpropercommunicationcablesetup.
6) Checkforsignsofpowersurges.
ERRORCODE991[510(T‐D2)],FIVEFLASHES/99[110(T‐KJR2),310(T‐K4)]
ABNORMALCOMBUSTION
1) Refertoerrorcode101.
2) ContacttheTechnicalServiceDepartmentforfurtherassistanceifnothinghasworkedsofar.The
manifoldgaspressuremayneedadjustment.
3) Ifyouaresurethattheproblemhasbeensolved,resetthecomputer(p.23).