12
6: To compare stable data which are ≥ +5d.
d = minimum display in kg (Refer to “13. SPECIFICATIONS”.)
In the counting mode, “d” is equal to the minimum weight display of kg mode.
8.1. The formula to compare
Comparison is performed using the formula listed below and the results are output.
Five-level comparator mode
Results Comparison formula LED display
LOLO Displayed value < LOLO limit, or “
-e
”
( Red LED on)
LO LOLO limit ≤ Displayed value < LO limit
( Yellow LED on)
OK LO limit ≤ Displayed value ≤ HI limit
( Green LED on)
HI HI limit < Displayed value ≤ HIHI limit
( Yellow LED on)
HIHI HIHI limit < Displayed value, or “
e
”
( Red LED on)
Three-level comparator mode
Results Comparison formula LED display
LO Displayed value < LO limit, or “
-e
”
( Red LED on)
OK LO limit ≤ Displayed value ≤ HI limit
( Green LED on)
HI HI limit < Displayed value, or “
e
”
( Red LED on)