EasyManua.ls Logo

A&D SJ-3000WP - The Formula to Compare

A&D SJ-3000WP
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
6: To compare stable data which are +5d.
d = minimum display in kg (Refer to “13. SPECIFICATIONS”.)
In the counting mode, “d” is equal to the minimum weight display of kg mode.
8.1. The formula to compare
Comparison is performed using the formula listed below and the results are output.
Five-level comparator mode
Results Comparison formula LED display
LOLO Displayed value < LOLO limit, or “
-e
( Red LED on)
LO LOLO limit Displayed value < LO limit
( Yellow LED on)
OK LO limit Displayed value HI limit
( Green LED on)
HI HI limit < Displayed value HIHI limit
( Yellow LED on)
HIHI HIHI limit < Displayed value, or “
e
( Red LED on)
Three-level comparator mode
Results Comparison formula LED display
LO Displayed value < LO limit, or “
-e
( Red LED on)
OK LO limit Displayed value HI limit
( Green LED on)
HI HI limit < Displayed value, or “
e
( Red LED on)

Related product manuals