EasyManua.ls Logo

ABB A175-L35 - Table 12 Volume of Water Per Cleaning; Table 13 Tightening Torques (81125)

ABB A175-L35
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A100-L
6
Periodic maintenance
Page 45 /
113
© Copyright 2016 ABB. All rights reserved.
HZTL4034_EN
Revision H
November 2016
Repeating the cleaning
If the cleaning is still unsuccessful after three processes, it is recommended to have the turbo-
charger checked and cleaned by an ABB Turbocharging Service Station if the engine values
are unsatisfactory.
Volume of water per cleaning process
Product
Quantity [dm
3
]
A165-L 2.0
A170-L 2.0
A175-L 3.0
A180-L 3.0
A185-L 3.0
A190-L 3.0
Table 12: Volume of water per cleaning process
The filling time is 4 ... 15 seconds.
Checking the filter plug
Figure 18: Filter plug view
Disassembly and checking of the filter plug (81125) is required if, 20 seconds after the clean-
ing process, water is still visible in filler opening B.
Loosen and remove the filter plug (81125) with box spanner
Clean the drill holes of the plug
Fit filter plug (81125).
Part number
A165-L
A170-L
A175-L
A180-L
A185-L
A190-L
81125 G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
G1/2"
45 Nm
Table 13: Tightening torques (81125)

Table of Contents

Related product manuals