98 E-Clipse Bypass Configurations for ACH550 Drives
Technical Data
Standard Enclosure, B1…B3
* Measurements are center to center.
Standard Enclosure, B4
Weights
The following table lists typical maximum weights for each frame size. Variations
within each frame size (due to components associated with voltage/current ratings,
and options) are minor.
Vertical Enclosure, V1...V4
Standard Enclosure, B1...B3
Dimensions for Each Frame Size
IP 21 / UL type 1 and IP 54 / UL type 12 – Mounting UL Type 3R
Ref.
B1 B2 B3 B1 B2
mm
in mm in mm in mm in mm in
W1* 44.3
17.4 400 15.7 600 23.6 320 12.6 400.0 15.7
H1* 810
31.9 918 36.1 1175 46.3 810 31.9 917.9 36.1
Mounting Hardware
M10
3/8 M10 3/8 M10 3/8 M10 3/8 M10 3/8
IP 21 / UL type 1 and IP 54 / UL type 12 – Dimensions for each Frame Size
Ref.
B4
Top View
mm
in
W 806
31.7
D 659 25.9
a 675
26.6
b 474.5 18.7
c 55.5 2.2
d 65.5
2.6
Mounting Hardware
11 mm
13/32
Enclosure
Weight
V1 V2 V3 V4
kg
lb. kg lb. kg lb. kg lb.
IP 21 /
UL type 1
18
40 23 50 51 112 59 131
Enclosure
Weight
B1/R1 B1/R2 B2/R3 B2/R4 B3/R5 B3/R6
kg lb. kg lb. kg lb. kg lb. kg lb. kg lb.
IP 21 /
UL type 1
35
78 38 84 54 120 63 138 121 266 163 360
IP 54 /
UL type 12
35
78 38 84 56 123 64 141 123 271 166 365
IP /
UL type 3R
58
128 61 134 80 175 88 193 Consult Factory
W
D
b
a
c
D
d

Table of Contents

Related product manuals