Loading...
ACH550 E-Clipse Bypass User’s Manual 2-9
Installation
The following is a typical power diagram.
Installation flow chart
The installation of E-Clipse Bypass Configurations for ACH550 drives follows the
outline below. The steps must be carried out in the order shown. At the right of each
step are references to the detailed information needed for the correct installation of
the unit.
Task
Reference in ACH550-UH
Users Manual
Installation section
Reference in this Manual
PREPARE for installation Preparing for installation Drive identification on page 2-10.
Suitable mounting location
(supplement to ACH550-UH User’s
Manual) on page 2-11
PREPARE the mounting
location
Prepare the mounting
location
MOUNT the unit Mount the drive
REMOVE the covers
from Vertical E-Clipse
Bypass Unit
Remove front cover
INSTALL wiring Wiring overview and
Install the wiring
Installing the wiring (supplement to
ACH550-UH User’s Manual) starting
on page 2-11.
CHECK jumpers and
switches
Check E-Clipse Bypass jumpers and
switches on page 2-28.
CHECK installation Check installation Initial settings and checks on
page 2-22.
RE-INSTALL the covers Re-install cover
APPLY power Apply power
START-UP Start-up Start-up on page 2-33.
ACH550
Drive with E-Clipse Bypass
Motor
3 Phase
Drive
3
3
Disconnect Switch
or Circuit Breaker
Service Switch
(Optional)
Input Power
Bypass
Contactor
Bypass
Control
Drive Output
Contactor
Drive Input Fuse

Table of Contents