E-Bypass Configurations for ACH550 Drives 7
Installation
Preparing for Installation (Supplement to ACH550-UH User’s Manual)
Drive Identification
Drive Labels
To determine the type of drive you are installing, refer to either:
• Serial number label attached on
upper part of the chokeplate
between the mounting holes.
• Type code label attached on the
heat sink – on the right side of the
unit cover.
Type Code
Use the following chart to interpret the type code found on either label.
Ser. no.
ACH550-BC-316A-4
*2030700001*
U1
I2N
PN
100 A
400
3~ 200...280 V
2042500001
Input
Voltage (U1)
Current (I1ND)
3 Phase 48…63 Hz
200…240 V
100 A
1 Phase 48…63 Hz
200…240 V
100 A
Outpu t
Voltage (U2)
Current (I2ND)
3 Phase 48…63 Hz
0…Input Voltage (U1)
100 A
1 Phase 48…63 Hz
0…Input Voltage (U1)
100 A
UL Type 12 / IP54
ACH550–BC–100A–2+K454+L502+L503+N661+P901
Nominal Motor
Power (PND)
Short Circuit Rating
Mfg. Date: June 10, 2004 Org. Firmware: V.2.03B
ABB Inc.
Made in USA with foreign parts
OEM Part Number
15 HP
100 kAIC
400 HP
100 kAIC
ACH550-BC-316A-4+…+…
AC, HVAC Drive – 550 product series
4 = 380…480 VAC
BC = E-Bypass with circuit breaker
2 = 208…240 VAC
Construction
Output current rating (See Ratings chart for details)
Voltage rating
UH = Base drive
Enclosure protection class
No specification = IP 21 / UL type 1
+B055 = IP 54 / UL type 12
BD = E-Bypass with disconnect switch
PC = Drive with circuit breaker
PD = Drive with disconnect switch
VC = Vertical E-Bypass with circuit breaker
VD = Vertical E-Bypass with disconnect switch
Line reactor
+E213 = Line Reactor
Service Switch
+F267 = Service switch
Fieldbus Adapters
+K451 = DeviceNet Adapter
+K452 = LonWorks Adapter
+K454 = Profibus Adapter
6 = 500…600 VAC