7
Ratings and fuses
I
II
Type
ACH580
Input
rating
Output ratings Heat
dissipation
Air flow Frame
size
Nominal use
-01-
I
1N
I
N
P
N
A A kW W
m
3
/h
3-phase U
N
= 400 V (380…415 V)
02A6-4 2.6 2.6 0.75 45 34 R0
03A3-4 3.3 3.3 1.1 55 34 R0
04A0-4 4.0 4.0 1.5 66 34 R0
05A6-4 5.6 5.6 2.2 84 34 R0
07A2-4 7.2 7.2 3.0 106 50 R1
09A4-4 9.4 9.4 4.0 133 50 R1
12A6-4 12.6 12.6 5.5 174 50 R1
017A-4 17 17 7.5 228 128 R2
025A-4 25 25 11.0 322 128 R2
032A-4 32 32 15.0 430 116 R3
038A-4 38 38 18.5 525 116 R3
045A-4 45 45 22.0 619 116 R3
3AXD00000586715.xls G
Type
ACH580
Input
rating
Output ratings Heat
dissipation
Air flow Frame
size
Nominal use Heavy duty use
-01-
I
1N
I
Ld
P
Ld
I
Hd
P
Hd
A A hp A hp W
m
3
/h
3-phase U
N
= 480 V (440…480 V)
02A6-4 2.1 2.1 1.0 1.6 0.75 45 34 R0
03A3-4 3.0 3.0 1.5 2.1 1.0 55 34 R0
04A0-4 3.4 3.4 2.0 3.0 1.5 66 34 R0
05A6-4 4.8 4.8 3.0 3.4 2.0 84 34 R0
07A2-4 6.0 6.0 3.0 4.0 3.0 106 50 R1
09A4-4 7.6 7.6 5.0 4.8 3.0 133 50 R1
12A6-4 11 .0 11.0 7.5 7.6 5.0 174 50 R1
017A-4 14 14.0 10.0 11.0 7.5 228 128 R2
025A-4 21 21.0 15.0 14.0 10.0 322 128 R2
032A-4 27 27.0 20.0 21.0 15.0 430 116 R3
038A-4 34 34.0 25.0 27.0 20.0 525 116 R3
045A-4 40 40.0 30.0 34.0 25.0 619 116 R3
3AXD00000586715.xls G
3AUA0000076330 Rev A