Installation
Type Code
Use the following chart to interpret the type code found on either label.
Ratings and Frame Size
The chart in "Ratings"
on page 211 lists technical specifications, and identifies the
drive’s frame size – significant, since some instructions in this document, vary,
depending on the drive’s frame size. To read the Ratings table, you need the “Output
current rating” entry from the type code. Also, when using the Ratings table, note
that the table is broken into sections based on the drive’s “Voltage rating”.
Motor Compatibility
The motor, drive, and supply power must be compatible:
Tools Required
To install the ACS510 you need the following:
Screwdrivers (as appropriate for the mounting hardware used)
Wire stripper
Motor
Specification
Verify Reference
Motor type 3-phase induction motor
Nominal current Motor value is within this
range: 0.2…2.0 * I
2n
Type code label on drive, entry for Output I
2n
,
or
Type code on drive and rating table in
"Technical Data" on page 211.
Nominal frequency 10…500 Hz
N688:10...50Hz
N689:10...55Hz
Voltage range Motor is compatible with
the ACS510 voltage range.
380…480 V
ACS510-01-09A4-4+...
AC, Standard Drive – 510 product series
e.g. 09A4 = 9.4A, see Ratings chart for details
4 = 380…480 VAC
Construction (region specific)
Output current rating
Voltage rating
01 = Wall mounting (Setup and parts specific to IEC installation and compliance)
Degree of protection Enclosure and/or other options
No specification = IP21
B055 = IP54
N688 = GO-mark approval with 50Hz limit
N689 = GO-mark approval with 55Hz limit