408 Parameters
93.11 Absolute position
source
(Visible when an absolute encoder is selected)
See parameter 92.11 Absolute position source.
None
93.11 Excitation signal
amplitude
(Visible when a resolver is selected)
See parameter 92.11 Excitation signal amplitude.
4.0 V
93.12 Speed calculation
mode
(Visible when a TTL, TTL+ or HTL encoder is selected)
See parameter 92.12 Speed calculation mode.
Auto rising
93.12 Zero pulse enable (Visible when an absolute encoder is selected)
See parameter 92.12 Zero pulse enable.
Disable
93.12 Resolver polepairs (Visible when a resolver is selected)
See parameter 92.12 Resolver polepairs.
1
93.13 Position estimation
enable
(Visible when a TTL, TTL+ or HTL encoder is selected)
See parameter 92.13 Position estimation enable.
Enable
93.13 Position data width (Visible when an absolute encoder is selected)
See parameter 92.13 Position data width.
0
93.14 Speed estimation
enable
(Visible when a TTL, TTL+ or HTL encoder is selected)
See parameter 92.14 Speed estimation enable.
Disable
93.14 Revolution data
width
(Visible when an absolute encoder is selected)
See parameter 92.14 Revolution data width.
0
93.15 Transient filter (Visible when a TTL, TTL+ or HTL encoder is selected)
See parameter 92.15 Transient filter.
4880 Hz
93.17 Accepted pulse freq
of encoder 2
(Visible when parameter 93.01 Encoder 2 type = HTL 1 or
HTL 2)
See parameter 92.17 Accepted pulse freq of encoder 1
.
0 kHz
93.21 Encoder cable fault
mode
(Visible when a TTL, TTL+ or HTL encoder is selected)
See parameter 92.21 Encoder cable fault mode.
A, B
93.23 Maximum pulse
waiting time
(Visible when parameter 93.01 Encoder 2 type = TTL or HTL)
See parameter 92.23 Maximum pulse waiting time.
4 ms
93.24 Pulse edge filtering (Visible when parameter 93.01 Encoder 2 type = HTL)
See parameter 92.24 Pulse edge filtering.
No filtering
93.25 Pulse
overfrequency
function
(Visible when parameter 93.01 Encoder 2 type = HTL)
See parameter 92.25 Pulse overfrequency function.
Fault
93.30 Serial link mode (Visible when an absolute encoder is selected)
See parameter 92.30 Serial link mode.
Initial position
93.31 EnDat calc time (Visible when an absolute encoder is selected)
See parameter 92.31 EnDat max calculation time.
50 ms
93.32 SSI cycle time (Visible when an absolute encoder is selected)
See parameter 92.32 SSI cycle time.
100 us
93.33 SSI clock cycles (Visible when an absolute encoder is selected)
See parameter 92.33 SSI clock cycles.
2
93.34 SSI position msb (Visible when an absolute encoder is selected)
See parameter 92.34 SSI position msb.
1
93.35 SSI revolution msb (Visible when an absolute encoder is selected)
See parameter 92.35
SSI revolution msb.
1
93.36 SSI data format (Visible when an absolute encoder is selected)
See parameter 92.36 SSI data format.
Binary
93.37 SSI baud rate (Visible when an absolute encoder is selected)
See parameter 92.37 SSI baud rate.
100 kBit/s