EasyManua.ls Logo

ABB ACS880-17 - LSU Control

ABB ACS880-17
604 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional parameter data 491
93.11 Pulse encoder type uint16 0…1 - 1 = 1
93.12 Speed calculation mode uint16 0…5 - 1 = 1
93.13 Position estimation enable uint16 0…1 - 1 = 1
93.14 Speed estimation enable uint16 0…1 - 1 = 1
93.15 Transient filter uint16 0…3 - 1 = 1
93.17 Accepted pulse freq of
encoder 2
uint16 0…300 kHz 1 = 1 kHz
93.21 Encoder cable fault mode uint16 0…3 - 1 = 1
93.23 Maximum pulse waiting time real32 1…200 ms 1 = 1 ms
93.24 Pulse edge filtering uint16 0…2 - 1 = 1
93.25 Pulse overfrequency function uint16 0…1 - 1 = 1
Other parameters in this group when an absolute encoder is selected
93.10 Sine/cosine number uint16 0…65535 - 1 = 1
93.11 Absolute position source uint16 0…5 - 1 = 1
93.12 Zero pulse enable uint16 0…1 - 1 = 1
93.13 Position data width uint16 0…32 - 1 = 1
93.14 Revolution data width uint16 0…32 - 1 = 1
93.30 Serial link mode uint16 0…2 - 1 = 1
93.31 EnDat calc time uint16 0…3 - 1 = 1
93.32 SSI cycle time uint16 0…5 - 1 = 1
93.33 SSI clock cycles uint16 2…127 - 1 = 1
93.34 SSI position msb uint16 1…126 - 1 = 1
93.35 SSI revolution msb uint16 1…126 - 1 = 1
93.36 SSI data format uint16 0…1 - 1 = 1
93.37 SSI baud rate uint16 0…5 - 1 = 1
93.40 SSI zero phase uint16 0…3 - 1 = 1
93.45 Hiperface parity uint16 0…1 - 1 = 1
93.46 Hiperface baud rate uint16 0…3 - 1 = 1
93.47 Hiperface node address uint16 0…255 - 1 = 1
Other parameters in this group when a resolver is selected
93.10 Excitation signal frequency uint16 1…20 kHz 1 = 1 kHz
93.11 Excitation signal amplitude uint16 4.0 … 12.0 V 10 = 1 V
93.12 Resolver polepairs uint16 1…32 - 1 = 1
94 LSU control
(Group only visible when supply unit control activated by 95.20)
94.01 LSU control uint16 0…1 - 1 = 1
94.02 LSU panel communication uint16 0…1 - 1 = 1
(Parameter 94.04 only visible with certain drive types)
94.04 INU-LSU status word profile uint16 0…1 - 1 = 1
94.10 LSU max charging time uint16 0…65535 s 1 = 1 s
94.11 LSU stop delay uint16 0.0 3600.0 s 10 = 1 s
No. Name Type Range Unit FbEq32