Additional parameter data 495
99.10 Motor nominal power real32 0.00 … 10000.00 kW or
0.00 13404.83 hp
kW or hp 100 = 1 unit
99.11 Motor nominal cos Φ real32 0.00 1.00 - 100 = 1
99.12 Motor nominal torque uint32 0.000 4000000.000 N·m or
lb·ft
1000 = 1 unit
99.13 ID run requested uint16 0…7 - 1 = 1
99.14 Last ID run performed uint16 0…7 - 1 = 1
99.15 Motor polepairs calculated uint16 0…1000 - 1 = 1
99.16 Motor phase order uint16 0…1 - 1 = 1
99.18 Sine filter inductance real32 0.000 100000.000 mH 1000 = 1 mH
99.19 Sine filter capacitance real32 0.00 100000.00 µF 100 = 1 µF
200 Safety
This group contains parameters related to the optional FSO-xx safety functions module. For details, refer to
the documentation of the FSO-xx module.
206 I/O bus configuration
207 I/O bus service
208 I/O bus diagnostics
209 I/O bus fan identification
(Groups only visible with a BCU control unit) These groups contain parameters related to the distributed I/O
bus, which is used with some drives for monitoring the cooling fans of the cabinet system. For details, refer
to ACS880 distributed I/O bus supplement (3AXD50000126880 [English]).
No. Name Type Range Unit FbEq32