Additional parameter data 459
16.30 AI1 unit selection uint16 --1 = 1
16.31 AI1 filter gain uint16 0…7 - 1 = 1
16.32 AI1 filter time real32 0.000 … 30.000 s 1000 = 1 s
16.33 AI1 min real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.34 AI1 max real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.35 AI1 scaled at AI1 min real32 -32768.000 … 32767.000 - 1000 = 1
16.36 AI1 scaled at AI1 max real32 -32768.000 … 32767.000 - 1000 = 1
16.41 AI2 actual value real32 -22.000 22.000 mA or V 1000 = 1 unit
16.42 AI2 scaled value real32 -32768.000 … 32767.000 - 1000 = 1
16.43 AI2 force data real32 -22.000 22.000 mA or V 1000 = 1 unit
16.44 AI2 HW switch position uint16 --1 = 1
16.45 AI2 unit selection uint16 --1 = 1
16.46 AI2 filter gain uint16 0…7 - 1 = 1
16.47 AI2 filter time real32 0.000 … 30.000 s 1000 = 1 s
16.48 AI2 min real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.49 AI2 max real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.50 AI2 scaled at AI2 min real32 -32768.000 … 32767.000 - 1000 = 1
16.51 AI2 scaled at AI2 max real32 -32768.000 … 32767.000 - 1000 = 1
AI3 (16.01 Module 3 type = FIO-11)
16.56 AI3 actual value real32 -22.000 22.000 mA or V 1000 = 1 unit
16.57 AI3 scaled value real32 -32768.000 … 32767.000 - 1000 = 1
16.58 AI3 force data real32 -22.000 22.000 mA or V 1000 = 1 unit
16.59 AI3 HW switch position uint16 --1 = 1
16.60 AI3 unit selection uint16 --1 = 1
16.61 AI3 filter gain uint16 0…7 - 1 = 1
16.62 AI3 filter time real32 0.000 … 30.000 s 1000 = 1 s
16.63 AI3 min real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.64 AI3 max real32 -22.000 22.000 mA or V 1000 = 1 mA
or V
16.65 AI3 scaled at AI3 min real32 -32768.000 … 32767.000 - 1000 = 1
16.66 AI3 scaled at AI3 max real32 -32768.000 … 32767.000 - 1000 = 1
Common parameters for AOx (
16.01 Module 3 type = FIO-11 or FAIO-01)
16.71 AO force selection uint16 00000000h…FFFFFFFFh - 1 = 1
AO1 (16.01 Module 3 type = FIO-11 or FAIO-01)
16.76 AO1 actual value real32 0.000 … 22.000 mA 1000 = 1 mA
16.77 AO1 source uint32 --1 = 1
16.78 AO1 force data real32 0.000 … 22.000 mA 1000 = 1 mA
16.79 AO1 filter time real32 0.000 … 30.000 s 1000 = 1 s
No. Name Type Range Unit FbEq32