EasyManua.ls Logo

ABB aquamaster - MIL Connector Input;Output (Option) Aquamag X10 Pulse Output Compatibility; Scanreader Interface (Option)

ABB aquamaster
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electronic Commercial Water Meter
AquaMaster™ 3 Electrical Installation
IM/AM Issue 13 27
3.3.4 MIL Connector Input/Output (Option) AquaMag™ x10 Pulse Output Compatibility
Where an existing installation has been wired to operate from the x10 outputs of an AquaMag™, the wiring
of the AquaMaster™ connector can be altered to suit – see Fig. 3.19.
3.3.5 ScanReader Interface (Option)
Fig. 3.19 MIL Connector Input/Output Connections
Note. Some data logger leads contain components which convert forward and reverse pulses into a
single pulse line with a direction signal. Such leads will NOT work with AquaMaster and are unnecessary
as AquaMaster directly provides the correct signals for these loggers.
Fig. 3.20 ScanReader Connections
Terminal AquaMag/ AquaMag x10
AquaMag x1
COM Grey/Blue Grey/Blue
O/P 1 Orange White/Red
O/P 2 Blue White/Black
COM
O/P1
O/P2
O/P3
2-Wire Pad Connection
1.5 m to 40 m
Recommended Cable
ABB STT4009
(or equivalent)
Data
0V
3-Wire Transponder Connection
Data
0V
Transponder
+V
3-terminal PCB
WADX2026
Reading Pad
Cable Colors
Green +V
Red Data
Black 0V

Other manuals for ABB aquamaster