Questions and Answers

  • W
    wdavisAug 16, 2025
    What to do if ABB Measuring Instruments show 'MEASURING RANGE EXCEEDED'?
    • S
      samuel80Aug 16, 2025
      If the ABB Measuring Instruments display 'MEASURING RANGE EXCEEDED', it means the current measurement is beyond the instrument's capacity. To resolve this, choose another type of reagent within the Basic program settings.
  • L
    Leslie ClarkAug 19, 2025
    What to do if ABB AW101 Measuring Instruments show 'REAGENT LOW'?
    • V
      vthompsonAug 19, 2025
      If the ABB Measuring Instruments indicates 'REAGENT LOW', it means the reagent level is below the minimum threshold: 50 ml (10%) without BOB, or a calculated value with BOB. To fix this, check the reagent level and refill if necessary. Then, enter the new level in the system by navigating to M ? SERVICE.
  • E
    Eric AyalaAug 22, 2025
    Why is there low water pressure in my ABB Measuring Instruments?
    • C
      cevansAug 22, 2025
      Low water pressure in your ABB Measuring Instruments can occur due to several reasons: no water input even when LED I is lit, inlet pressure being too low, overflow reagent not being active, or an oxidized connector on the inlet valve. Resolve this by checking the water inlet, cleaning the filter strainer, replacing the valve block, extracting the pressure regulator valve, or carrying out an adjustment.
  • R
    Robert HarmonAug 26, 2025
    What to do if ABB AW101 show 'Ff. DOSING FAULT'?
    • B
      Brian MooreAug 26, 2025
      If the ABB Measuring Instruments display 'Ff. DOSING FAULT', it indicates a dosing inaccuracy with the dosing pump. Correct this by replacing the dosing pump or returning it to the supplier for calibration.
  • K
    Kevin HughesAug 28, 2025
    What to do if ABB AW101 show 'Ff. OUTLET TO DRAIN'?
    • P
      Paul EsparzaAug 28, 2025
      If the ABB Measuring Instruments displays 'Ff. OUTLET TO DRAIN', it means water remains in the measuring chamber even when the LED OUT is lit. To address this, check the water outlet and replace the valve block if the connector of the outlet valve is oxidized.
  • A
    Alexandra RiceAug 31, 2025
    What to do if ABB Measuring Instruments show 'Mf. ANALYSIS' error?
    • X
      xweberAug 31, 2025
      If the ABB Measuring Instruments displays 'Mf. ANALYSIS' error, it may be due to an incorrect analysis caused by issues such as air in the dosing capillary, incomplete blending, or using old or third-party reagents. To resolve this, tighten the connections of the dosing pump, replace the stirring mechanism, replace the suction insert in the bottle, and use only ABB reagent.
  • R
    Ruth QuinnSep 3, 2025
    How to fix 'Ff. DOSING PUMP' error in ABB Measuring Instruments?
    • D
      David MackSep 3, 2025
      To fix the 'Ff. DOSING PUMP' error in ABB Measuring Instruments, check the cable connection to the dosing pump to ensure it is correct. If the dosing pump is defective, replace it.
  • B
    Brian JohnsonSep 6, 2025
    What to do if ABB AW101 Measuring Instruments show 'Ff. OPTICS' error?
    • M
      mcphersonjohnSep 6, 2025
      If the ABB Measuring Instruments displays 'Ff. OPTICS' error, it could be due to a defective plug-in circuit board or an issue with the optic component (transmitter or receiver). To resolve this, replace the plug-in circuit board or replace the measuring chamber sealing rings.
  • J
    Jennifer FullerSep 9, 2025
    What causes 'Mf. TURBID' error in ABB AW101?
    • B
      Brent WrightSep 9, 2025
      The 'Mf. TURBID' error in ABB Measuring Instruments indicates that the water being measured is turbid or dirty. No direct solution.
  • M
    Monica MorrisonSep 12, 2025
    How to resolve 'Mf. DIRTINESS' issue in ABB AW101?
    • S
      Shannon AriasSep 12, 2025
      The 'Mf. DIRTINESS' issue in ABB Measuring Instruments occurs when the sight-glass windows are dirty. To resolve this, clean the sight-glass windows.