CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | CI/FCB400/FCH400-EN REV. H 11
ATEX / IECEx
Note
A specific marking applies, depending on the design.
ABB reserves the right to modify the Ex-marking. Refer to the name plate for the exact marking.
Model number for use in Zone 2, 21 Ex marking Certificate
FCa4c – A2Y0fghijD
Integral mount design with dual-compartment housing
II3G Ex ec IIC T6...T1 Gc
II2D Ex tb IIIC T80°C...Tmedium Db
ATEX:
FM15ATEX0014X, FM15ATEX0016X
IECEx:
IECEx FME 15.0005X
FCa4c – A2efghijY
Sensor in remote mount design with dual-compartment
housing
FCT4c – A2R
Transmitter in remote mount design with dual-
compartment housing
II3G Ex ec IIC T6 Gc
II2D Ex tb IIIC T80°C Db
Model number for use in Zone 1, 21 Ex marking Certificate
FCa4c – A1Y0fghijDx (x = 1 to 4)
Integral mount design with dual-compartment housing
II 1/2 (1) G Ex db eb ia mb [ia Ga] IIC T6…T1 Gb
II 2 (1) D Ex ia tb [ia Da] IIIC T80°C Db
ATEX:
FM15ATEX0015X
IECEx:
IECEx FME 15.0005X
FCa4c – A1Y0fghijDx (x = 5 to 8)
Integral mount design with dual-compartment housing
(flameproof enclosure ‘Ex d’)
II 1/2 (1) G Ex db ia mb [ia Ga] IIB+H2 T6...T1 Gb
II 2 (1) D Ex ia tb [ia Da] IIIC T80°C Db
FCa4cA1Y0fghM6jDx (x=1 to 4) or DRH or DSH option
card
Integral mount design with dual-compartment housing
and active digital output option card
II 1/2 (1) G Ex db eb ia mb IIC T6…T1 Gb
II 2 (1) D Ex eb tb IIIC T80°C Db
FCa4c – A1efghijY
Sensor in remote mount design with dual-compartment
housing
II 1/2 G Ex eb ia mb IIB+H2 T6…T1 Ga/Gb
II 2 D Ex ia tb IIIC T80°C Db
FCa4cA1Y0fghM6jDx (x=5 to 8) or DRH or DSH option
card
Integral mount design with dual-compartment housing
(flameproof enclosure ‘Ex d’) and active digital output
option card
II 1/2 (1) G Ex db ia mb IIB+H2 T6...T1 Gb
II 2 (1) D Ex ia tb IIIC T80°C Db
FCT4c – A1R (x = 1 to 4)
Transmitter in remote mount design with dual-
compartment housing
II 2 (1) G Ex db e ia mb [ia Ga] IIC T6…T1 Gb
II 2 (1) D Ex ia mb tb [ia Da] IIIC T80°C Db
FCT4c – A1R (x = 5 to 8)
Transmitter in remote mount design with dual-
compartment housing
(flameproof enclosure ‘Ex d’)
II 2 (1) G Ex db ia mb [ia Ga] IIB+H2 T6…T1 Gb
II 2 (1) D Ex ia tb [ia Da] IIIC T80°C Db
FCT4c – A1R (x = 1 to 4) fghM6 or DRH or DSH option
card
Transmitter in remote mount design with dual-
compartment housing and active digital output option
card
II 2 (1) G Ex db eb ia mb IIC T6…T1 Gb
II 2 (1) D Ex ia mb tb IIIC T80°C Db
FCT4c – A1R (x = 5 to 8)fghM6 or DRH or DSH option
card
Transmitter in remote mount design with dual-
compartment housing (flameproof enclosure ‘Ex d’) and
active digital output option card
II 2 (1) G Ex db ia mb IIB+H2 T6…T1 Gb
II 2 (1) D Ex ia tb IIIC T80°C Db

Table of Contents

Other manuals for ABB CoriolisMaster FCB400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB CoriolisMaster FCB400 Series and is the answer not in the manual?

ABB CoriolisMaster FCB400 Series Specifications

General IconGeneral
BrandABB
ModelCoriolisMaster FCB400 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals