Loading...
10
3ADW000191R0500 DCS800 Quick guide edisf e
X2:
X1:
ATACH
±90...
±
270 V
±
30...
±
90 V
±
8...
±
30 V
AI4
(5 ms)
GND
GND
39k2
+10V
Power
Sense 0 V
Sense 5 V
AI3
(5 ms)
AI1
(3.3 ms)
+/- I-act
47.5
100
µ
100n
GND (AOx)
+10V
GND
-10V
DI1
DI3
DI4
DO4
DO5
DO1
4k75
3
4
5
6
9
X6:1
3
4
10
4
5
1
2
3
6
5
10
8
9
10
5
2
6
8
10
8
X3:1
X4:1
X5:1
X7:
SDCS-CON-4
Firmware
GND
1
3
S1
Con4_I_O-b.dsf
12k8
5k
1k66
+
-
4
6
S1
S2
3
4
250
S3
56
78
S3
3
4
250
+
-
SDCS-IOB-3
(PS5311)
9
8
7
ATACH1
ATACH2
S1
+
-
+
-
+
-
+
-
GND
1
3
S4
2
121
100nF
4
6
S4
5
121
100nF
7
10
S4
8
121
100nF
10k
10k
10k
+
-
+
-
+
-
PIN-4
= 5 V
S4
11
12
2k21 221k
4k75
47nF
Z15
+
-
5 V
Relay driver
Relay driver
Relay driver
Relay driver
Relay driver
Relay driver
Relay driver
X
9
τ
= 10 ms
τ
= 10 ms
τ
= 10 ms
τ
= 10 ms
τ
= 10 ms
τ
= 3
.
3 ms
τ
= 3
.
3 ms
ChA
ChB
ChZ
ChA
ChB
ChZ
POW-4
=
5V/
15V/24V
CON-4
= 24 V
Resolution
[bit]
Input/output
values
Hardware
Scaling
by
Common
mode
range
Remarks
15 + sign ±90...270 V
±30...90 V
±8...30 V
Firmware
±15 V
15 + sign -10...0...+10 V Firmware ±15 V
15 + sign -10...0...+10 V Firmware ±15 V
15 + sign -10...0...+10 V Firmware ±15 V
15 + sign -10...0...+10 V Firmware ±15V
Power
+10 V 5 mA
for ext. use
e.g. refer. pot.
-10 V 5 mA
11 + sign -10...0...+10 V Firmware 5 mA
11 + sign -10...0...+10 V Firmware 5 mA
-10...0...+10 V Firmware+
Hardware
5 mA
8 V -> min. of
325% of [99.03] or
230% of [4.05]
Encoder supply
Remarks
Inputs not isolated
Impedance = 120 W, if selected
max. frequence 300 kHz
5 V
24 V
250 mA
250 mA
Sense lines for GND and supply
to correct voltage drops on cable
(only if 5 V encoder is in use).
Input value
Signal
definition by
Remarks
0...7.3 V
7.5...50 V
Firmware
-> “0“ status
-> “1“ status
Output value
Signal
definition by
Remarks
50 * mA
22 V at no
load
Firmware
Current limit for all 7
outputs = 160 mA
Do not apply any reverse
voltages!
* short circuit protected
gain can be varied in 15 steps between 1 and 4 by software parame-
ter
Standard function assignments for the terminals