EasyManua.ls Logo

ABB IRB 14000 - Page 55

ABB IRB 14000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Action
If the hall sensor can not be found, following error message is displayed.
xx1400002698
3
There can be several causes for this error.
The joints are not sufficiently aligned according to the synchronization
marks. Move the joints so that the synchronization marks are aligned. Tap
OK and restart the fine calibration procedure. The joints prior to the joint
that stopped the calibration procedure are calibrated and do not need to
be calibrated again. Joints coming after the joint that stopped the calibration
procedure has not been calibrated. (Calibration order: axis 1-2-3-4-5-6-7.)
The hall sensor is defect. Perform troubleshooting of I/O signals. Possible
replacement of hall sensor may be required.
Operating manual - IRB 14000 55
3HAC052986-001 Revision: E
© Copyright 2015-2018 ABB. All rights reserved.
4 Calibration
4.3 Updating revolution counters
Continued

Other manuals for ABB IRB 14000

Related product manuals