4 Repair
4.6.4. Replacement of motor, axis 4
3213HAC026876-001 Revision: C
© Copyright 2006-2008 ABB. All rights reserved.
Removal, motor axis 4
The procedure below details how to remove the motor, axis 4.
Calibration
Pendulum toolkit
3HAC15716-1 Complete kit that also
includes operating manual.
Other tools and
procedures may be
required. See
references to these
procedures in the
step-by-step
instructions below.
These procedures include
references to the tools
required.
Circuit Diagram 3HAC025744-001 See chapter Circuit diagram.
Equipment, etc. Spare part no. Art. no. Note
Action Note
1. Move the robot to a position where the upper
arm is pointed straight up.
This position enables the motor to be
replaced without draining the gear oil, which
in turn saves time.
Any other position of the upper arm requires
a draining of oil from the gearbox for axis 4.
Draining of oil is described in section
Draining, oil on page 163.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
3. Remove the cable gland cover at the cable
exit of the motor by unscrewing its two
attachment screws.
Shown in the figure Location of motor on
page 320.
Make sure the gasket is not damaged!
4. Remove the cover on top of the motor by
unscrewing its four attachment screws.
5. Disconnect all connectors beneath the
motor cover.
6. In order to release the brake, connect the 24
VDC power supply.
Connect to connector R2.MP4
• +: pin 2
• -: pin 5
7. Unscrew the motors four attachment screws
and plain washers.
Shown in the figure Location of motor on
page 320.
8. Fit the two guide pins in two of the motor
attachment screw holes.
9. If required, press the motor out of position by
fitting removal tool, motor to the motor
attachment screw holes.
Art. no. is specified in Required
equipment on page 320.
Always use the removal tools in pairs!
Continued
Continues on next page