Specification of Variants and Options
Product Specification S4Cplus M2000/BaseWare OS 4.0 37
capacity 65 kA at 400V, 25 kA at 600V.
143 Rotary switch 80 A. Customer fuses for cable protection required.
Included in the option Prepared for Arcitec (112).
144 Servo disconnector.
This option adds a rotary switch 40 A to the two contactors in the AC power supply for
the drive system. The handle can be locked by a padlock, e.g. in an off position.
145 Door interlock for rotary switch.
Included in the options UL/CSA/UR (695, 696) and Servo disconnector (144).
147 Circuit breaker for rotary switch. A 16A (option 163 and 164) or 25A
(option 162) circuit breaker for short circuit protection of mains cables in the
cabinet. Circuit breaker approved in accordance with IEC 898, VDE 0660.
Interrupt capacity 6 kA.