Specification of Variants and Options
36 Product Specification S4Cplus M2000/BaseWare OS 4.0
Figure 17 Transformer unit (dimensions in mm).
MAINS CONNECTION TYPE
The power is connected either inside the cabinet or to a connector on the cabinet’s left-hand side.
The cable is not supplied. If option 133-136 is chosen, the female connector (cable part) is
included.
131 Cable gland for inside connection. Diameter of cable:
11-12 mm.
132 CEE17-connector 32 A, 380-415 V, 3p + PE (see Figure 18).
Not with Flange disconnector (142) or UL/UR (695/696) or
Service outlet power supply (432).
Not available for IRB 6600/7600.
Figure 18 CEE male connector.
133 32 A, 380-415 V, 3p + N + PE (see Figure 18).
Not with Flange disconnector (142) or UL/UR (695/696).
Not available for IRB 6600/7600.
134 Connection via an industrial Harting 6HSB connector in
accordance with DIN 41640. 35 A, 600 V, 6p + PE (see Figure 19).
Cannot be combined with Flange disconnector (142).
Figure 19 DIN male connector.
MAINS SWITCH
141 Rotary switch 40 A in accordance with the standard in section 1.2 and IEC 337-1,
VDE 0113. Customer fuses for cable protection required.
142 Flange disconnector in accordance with the standard in section 1.2.
Includes door interlock for flange disconnector and a 20A circuit breaker with interrupt capacity
14 kA.
0058 Flange disconnector in accordance with the standard in section 1.2.
Includes door interlock for flange disconnector and a 20A circuit breaker with interrupt
560
398300