4 On-site Installation
4.2.2 Mechanically restricting the working range of axis 1
62 A 3HAC 16245-1
4.2.2 Mechanically restricting the working range of axis 1
General The working range of axes 1 is limited by fixed mechanical stops and can be reduced by
adding additional mechanical stops giving 7.5 or 15 graduation in both directions.
Mechanical
stops, axis 1
The illustration below shows the mounting position of the mechanical stops on axis 1.
xx0300000049
Required equip-
ment
A Additional mechanical stop
B Fixed mechanical stop
A
B
Equipment, etc. Spare part no. Art. no. Note
7.5°, mechanical stop for axis 1 3HAC 11076-1 Includes attachment
screws.
15°, mechanical stop for axis 1 3HAC 11076-2 Includes attachment
screws.
Standard toolkit 3HAC 15571-1 The contents are
defined in the section
Standard toolkit on
page 18.