5 Electrical connections
5.4.2 External customer connections on panel X1 - X4
3HAC 16245-1 A 95
5.4.2 External customer connections on panel X1 - X4
Outline diagram The diagram shows the customer connections X1 - X4 located on the panel unit
xx0100000205
Connection of X1:
12-pole type
Phoenix COM-
BICON connector
The table below shows the signal descriptions for X1
The signal names refer to the Circuit Diagram.
Connection of X2:
12-pole type
Phoenix COM-
BICON connector
The table below shows the signal descriptions for X2
The signal names refer to the Circuit Diagram.
grey field Jumper
WARNING
REMOVE JUMPERS BEFORE CONNECTING
ANY EXTERNAL EQUIPMENT
Signal
Terminal
number
Comment
ES1 out: A 1 Emergency stop out chain 1
ES1 out: B 2 Emergency stop out chain 1
ES1 top 3 Top of emergency stop chain 1
24 V panel 4 + 24 V emergency stop chain 1 and run chain 1
Run ch1 top 5 Top of run chain 1
ES1 internal 6 Internal signal from emergency stop relay chain 1
Sep. ES1: A 7 Separated emergency stop chain 1
Sep. ES1: B 8 Separated emergency stop chain 1
ES1 bottom 9 Bottom of emergency stop chain 1
0 V 10 0 V emergency stop chain 1
Ext. LIM1: A 11 External limit switch chain 1
Ext. LIM1: B 12 External limit switch chain 1
Signal
Terminal
number
Comment
ES2 out: A 1 Emergency stop out chain 2