5 Electrical connections
5.4.2 External customer connections on panel X1 - X4
96 A 3HAC 16245-1
Connection of X3:
12-pole type
Phoenix COM-
BICON connector
The table below shows the signal descriptions for X2
The signal names refer to the Circuit Diagram.
Connection of X4:
12-pole type
Phoenix COM-
BICON connector
The table below shows the signal descriptions for X2
The signal names refer to the Circuit Diagram.
ES2 out: B 2 Emergency stop out chain 2
ES2 top 3 Top of emergency stop chain 2
0 V 4 0 V emergency stop chain 2
Run ch2 top 5 Top of run chain 2
ES2 internal 6 Internal signal from emergency stop relay chain 2
Sep. ES2: A 7 Separated emergency stop chain 2
Sep. ES2: B 8 Separated emergency stop chain 2
ES2 bottom 9 Bottom of emergency stop chain 2
24 V panel 10 + 24 V emergency stop chain 1 and run chain 2
Ext. LIM2: A 11 External limit switch chain 2
Ext. LIM2: B 12 External limit switch chain 2
Signal
Terminal
number
Comment
Signal
Terminal
number
Comment
Ext. MON 1: A 1 Motor contactor 1
Ext. MON 1: B 2 Motor contactor 1
0 V 3 External contactor 1 0 V
CONT1 4 External contactor 1
5 No connection
6 No connection
0 V 7 0 V to auto stop (AS) and general stop (GS)
GS1- 8 General stop minus chain 1
AS1- 9 Auto stop minus chain 1
GS1+ 10 General stop plus chain 1
AS1+ 11 Auto stop plus chain 1
24 V panel 12 24 V to auto stop and general stop
Signal
Terminal
number
Comment
Ext. MON 2: A 1 Motor contactor 2
Ext. MON 2: B 2 Motor contactor 2
24 V panel 3 External contactor 2 24 V
CONT2 4 External contactor 2
Ext. BRAKE A 5 Contactor for external brake
Ext. BRAKE B 6 Contactor for external brake