RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+
Section 2 Interface specications
* 100 Mbit/s or 1000 Mbit/s transceiver supported.
I/O Connection
Figure 9. I/O Connection
The status output is a potential free, opto-isolated normally c
losed solid-state
relay. This can be congured to monitor various alarm events within the NE804
unit, see NEOS User Manual. An external load in series with an external voltage
source is required for proper functionality. For voltage/current ratings, see Interface
specications section.
The Digital in is an opto-isolated digital input which can be used to monitor external
events. For voltage/current ratings, see Interface specications section.
3BSE080639 17
SFP Ports
Optical/Electrical
specication
IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s
Duplex Full or half, manual or auto
T
ransmission range Depending on transceiver
Connection SFP slot holding bre transceiver or copper transceiver