47 2TLC172001M0211_A
Indication:
Input/Output LED’s Controlled by processor
General
Enclosure
A20, B16, B20, S20, B22, D20, O2
and Pluto AS-i: 45 x 84 x 120 mm (w x h x d)
B46, S46, D45 and B42 AS-i: 90 x 84 x 120 mm (w x h x d)
Mounting DIN-Rail
Response time of dynamic A or static input (+24V)
Relay output Q0, Q1, (Q4, Q5): < 20.5 ms + prog. execution time
Solid state output Q2, Q3: < 16.5 ms + prog. execution time
Solid state output Q10..Q17: < 16.5 ms + prog. execution time
Response time of dynamic B or C inputs
Relay output Q0, Q1, (Q4, Q5): < 23 ms + prog. execution time
Solid state output Q2, Q3: < 19 ms + prog. execution time
Solid state output Q10..Q17: < 19 ms + prog. execution time
Response time Pluto O2 (From input in other Pluto to output in O2)
Relay output Q0, Q1: <33 ms + prog. execution time
Non-safe output Q10, Q11: < 29 ms + prog. execution time
Software setting ”NoFilt” Response times - 5 ms (5 ms less)
Response time AS-i bus:
Solid state output: <16.5 ms + prog. execution time
Relay output: <20.5 ms + prog. execution time
Response time AS-i bus at fault condition:
Solid state output: <29 ms (with setting “Short stop time”)
<39 ms (with setting “Disturbance immunity”)
Relay output: <33 ms (with setting “Short stop time”)
<43 ms (with setting “Disturbance immunity”)
Program execution time approximately 10µs/instruction
Extra response time over Pluto bus:
Normal condition 10 ms
Fault condition 10-40 ms
Q2, Q3 prolongation of response
time during fault condition: <10 ms
Detection time
Shortest detectable pulse on input: 10 ms
Ambient air temperature: -10°C - + 50°C
Temperature, transportation and storage: - 25 - +55°C
Operating altitude: Up to 2000 m
Humidity
EN 60 204-1: 50% at 40°C (ex 90% at 20°C)
Degree of protection, IEC 60 529
Enclosure: IP 40
Terminals: IP 20