T
1
3) 4)
[a]
Mis-
sion
time
[a]
CCFHFTCat.
DC
2)
[%]
PFD
avg
PFH
1)
[1/h]
PLSCSIL /
SIL-
CL
ContactorACS880-17/37
type
20/1206502>901.0E-39.6E-7d32AF400 /
AF580 /
AF750 /
AF1250 /
AF1650 or
AF2050 and
AF110-
A185 char-
ging contact-
or
-0450A-3
-0620A-3
-0870A-3
-1110A-3
-1210A-3
-1430A-3
-1700A-3
-2060A-3
-2530A-3
-0420A-5
-0570A-5
-0780A-5
-1010A-5
-1110A-5
-1530A-5
-1980A-5
-2270A-5
-0320A-7
-0390A-7
-0580A-7
-0660A-7
-0770A-7
-0950A-7
-1130A-7
-1450A-7
-1680A-7
-1950A-7
-2230A-7
-2770A-7
-3310A-7
3AXD10000097591 H
1)
PFH values are according to EN ISO 13849.
2)
In low demand mode, DC of electromechanical devices is considered as 0%, and therefore no overall DC value is claimed
in low demand mode.
3)
See the recommendation of use CNB/M/11.050 published by the European co-ordination of notified bodies for lower T
1
requirement.
4)
T
1
= 20a is used with high demand mode of operation. T
1
= 1a is used with low demand mode of operation.
Note: If T
1
> 1a is needed in low demand mode of operation, SIL 1 / PL c levels are used
and PFD is calculated separately.
48 Technical data