Description Parameter
(channel 0)
Setting range Default
setting
Customers
setting
Rear communication
protocol
V203 0 = SPA
1 = IEC_103
2 = Modbus RTU
3 = Modbus ASCII
0
Connection type V204 0 = loop
1 = star
0
Line-idle state V205 0 = light off
1 = light on
0
Optional communication
module
V206 0 = not in use
1 = in use
0
Table 8.-4 Parameters for the distu rbance recorder
Description Parameter
(channel 0)
Setting range Default
setting
Customers
setting
Sampling rate M15 800/960 Hz
400/480 Hz
50/60 Hz
800 Hz
Station identification/unit
number
M18 0...9999 0
Name of the motor drive M20 Max 16 characters - ABB -
Analog channel conversion
factor and unit for I
a
,I
b
and
I
c
M80, M81,
M82
Factor 0...65535,
unit (A, kA), e.g. 10,
kA
00001,CT
Analog channel conversion
factor and unit for the
ground-fault current
M83 Factor 0...65535,
unit (A, kA), e.g. 10,
kA
00001,CT
Internal trigger signals'
checksum
V236 0...8191 2728
Internal trigger signal's edge V237 0...8191 0
Checksum of internal signal
storing mask
V238 0...8191 6842
Post-triggering recording
length
V240 0...100% 50 %
External trigger signal's
checksum
V241 0...31 0
External trigger signal's
edge
V242 0...31 0
Checksum of external signal
storing mask
V243 0...31 0