Do you have a question about the ABB SACE PR010/T and is the answer not in the manual?
| Brand | ABB |
|---|---|
| Model | SACE PR010/T |
| Category | Test Equipment |
| Language | English |
Lists and describes the cables used to connect the PR010/T unit to various ABB SACE relays.
Details the tree menu structure for accessing functions and information on SACE relays.
Illustrates the connection of Cable A to a PR111 relay and IEC version of PR112 with key.
Illustrates the connection of Cable B to IEC and UL versions of PR112 relays.
Illustrates the connection of Cable C to a PR212/MP relay with a front connector.
Illustrates the connection of Cable D to a PR223EF relay.
Illustrates the connection of Cable E to a PR331 relay with a mechanical adapter.
Details the tree menu structure for accessing functions and information on SACE relays.
Describes common functions and characteristics accessible via the main menus.
Lists available tests for various SACE relays in this group.
Explains the procedure for performing a trip test with the circuit-breaker closed.
Details manual test configurations, parameter settings, and result display.
Explains the automatic test procedure for various phases and protections.
Describes testing SET and RESET outputs for PR212/CI unit.
Explains testing of Iinst protections in PR11x series relays.
Provides specific indications for performing tests correctly on various relays.
Notes on data entry, protection settings, and trip time tolerance for PR111/PR111/VF.
Notes on compatibility, G protection test, and contact wear for PR112.
Conditions for performing tests on PR113 relays.
Notes on manual test configurations for PR212 and PR222 relays.
Notes on test current, manual test, PTC, welded contacts, and thermal memory for PR212MP/PR222MP.
Notes on interlocking LEDs and EF protection deactivation for PR223EF.
Displays measurements in absolute values like Amperes and Volts.
Shows relay configuration, CB size, language, frequency, rated voltage, etc.
Displays the parameters of the main relay protections.
Stores data from the last tripping action, including current readings and total trips.
Contains relay name, SW release, and serial number.
Allows entering settings for CB size, frequency, neutral setting, and contacts.
Allows modification of protection parameters based on relay model and version.
Procedure to correct current readings in PR223DS relay via manual mode.
Configuring and reading status of S51/P1 and external contacts for PR223EF.
Details connection methods for New Emax, Tmax T7-8/Emax X1, and Emax DC relays.
Describes common menu structures and functions shared across PR12x units.
Lists available tests for various SACE relays in this group.
Details automatic test procedures for various relays, regardless of characteristics.
Explains manual test procedures for checking trip time under required load conditions.
Checks the opening system by transmitting a circuit-breaker opening command.
Tests contact modules (PR120/K, S51/P1) requiring auxiliary power.
Tests zone selectivity outputs for S and G protections with auxiliary power.
Tests residual current reading functionality using a simulated signal.
Various instantaneous measurements available for each relay.
Commands for resetting energy meters and measuring history.
Information recorded for each trip, including protection, date, time, and currents.
Records event descriptions and the date/time they were recorded.
Statistics include Contact Wear, Protection trips, Total operations, etc.
Lists configurable parameters like Circuit-breaker, HW trip, Alive LED, Frequency.
Procedure to change parameters using the keypad, including saving changes.
Accesses parameters like Neutral, Plant Configuration, CB TAG NAME, User Data, Toroid.
Configures the Alive LED signal for relay status indication.
Details Measuring, Communication, and Signalling module configurations.
Provides programmable contacts and controls activation signal settings.
Selects the presence/absence of a unit on the local bus.
Allows entering date/time and language settings for certain relays.
Shows availability of protections like S, G, Gext based on relay version.
Considers limitations for Startup time, current threshold, and unit contacts.
Protection settings cannot be changed if relay is in overcurrent Alarm or Pre-Alarm status.
Describes downloading information to a PC, including heading report details.
Explains freeing space and performing multiple downloads for comprehensive data.
Displays configuration/wiring error signals for protection unit and circuit-breaker.
Describes commands for exchanging information when replacing a relay.
Details automatic tests for relays without a measuring module.
Details automatic tests for relays with a measuring module.
Details automatic test procedures for PR123/P and PR333/P relays.
Details automatic test procedures for PR232/P and PR232/P-T8 relays.
Details automatic test procedures for PR122/DC relays.
Details automatic test procedures for PR123/DC relays.