Operation Manual / TPL67-C.. - TPL71-C..
Commissioning
3
Oil supply
3.1
Page 34
© Copyright 2016 ABB. All
rights reserved.
April 2016 HZTL2488_EN Revision C
Oil pressure
The oil pressure in front of the turbocharger must be maintained precisely
to ensure trouble-free operation.
The permissible oil pressure ranges at measuring point M (blind connec-
tion) on the turbocharger are listed below.
Status for operation
Oil pressure in front of the turbo-
charger [bar]
Permissible, for normal operation
1.32.5
Permissible, during engine warm-up 1.35.0
Temporarily permissible ( < 1h ) ->
alarm
1.11.3
Not permissible ->
emergency stop
0.01.1
Permissible, during pre- and post-lubrication
(engine stopped)
0.22.5
NOTICE
Oil orifice
To make sure these oil pressures are obtained, a regulating orifice is
fitted in the turbocharger oil inlet. The orifice is fitted by the engine
builder and secured by a safety ring.