EasyManua.ls Logo

ABB T566609 - Malfunctions When Stopping

ABB T566609
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / TPL67-C.. - TPL71-C..
Troubleshooting
6
Malfunctions when stopping
6.4
Page 72
© Copyright 2016 ABB. All rights reserved.
April 2016 HZTL2488_EN Revision C
Malfunctions when stopping
6.4
Noises during run-down
Possible causes
Elimination
Turbochar-
ger
Turbocharger contaminated Clean it
Damaged bearing
Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Run-down time too short
Possible causes
Elimination
Turbochar-
ger
Turbocharger contaminated
Clean it
Damaged bearing Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
6.4