RESOLVING ERRORS
21
3. Lock the cover shield again.
4. Now the EVSE5X2 cannot be used for charging.
PLEASE NOTE:
The EVSE 552 model variant has, in place of the integrated RCCB, a
switch that you can flick to position 0 to interrupt the Control-Pilot sig-
nal to the charging socket and thereby prevent detection of the electric
vehicle. Flick the switch to position I to restore communication between
charging station and vehicle via the CPsignal.
To deactivate your charging station permanently, please proceed as follows:
1. Open the cover shield using the key supplied.
2. Flick the pivot lever of the internal RCCB (if present) into the 0 position (connection
to the power supply is interrupted).
3. Lock the cover shield again.
4. In addition, switch off the miniature circuit breaker (MCB) in your upstream domes-
tic power distribution box (position 0).
5. Now the EVSE 5X2 is completely free of electricity and may be demounted if re-
quired.
PLEASE NOTE:
For model variants without RCCB, you must switch off the upstream
MCB in your domestic power distribution box to temporarily or perma-
nently deactivate the charging station.
WARNING!
The electrical de-installation of the EVSE 5X2 must always be carried out
by a qualified electrical contractor.
ENVIRONMENTAL NOTICE!
Please note that this product may not be disposed of in the household
garbage collection, but must be taken to a collection point for electrical/
electronic waste. Please observe all current national and regional legal
regulations. You can get further information from your municipal admin-
istration, the waste management depot responsible for your area as well
as from your local distributor.