SAFETY DATA SHEET
according to Regulation (EC) No. 1907/2006
CaH2 Typ K 0-2 mm - Lager
Version: 2.2 Revision Date 10.03.2017
Print Date 23.03.2018
3 / 11
DE
General advice :
First Aid responders should pay attention to self-protection
and use the recommended protective clothing
Take off contaminated clothing and shoes immediately.
Move out of dangerous area.
Keep warm and in a quiet place.
If inhaled :
Provide fresh air.
If not breathing, give artificial respiration.
Keep the victim calm and in a semi-upright position.
Call a physician immediately.
In case of skin contact :
Wash off immediately with plenty of water for at least 15
minutes.
Consult a physician.
In case of eye contact :
Rinse immediately with plenty of water, also under the eyelids,
for at least 15 minutes.
Call a physician immediately.
If swallowed :
Clean mouth with water and drink afterwards plenty of water.
Never give anything by mouth to an unconscious person.
Do NOT induce vomiting.
Call a physician immediately.
4.2 Most important symptoms and effects, both acute and delayed
Symptoms :
No information available.
4.3 Indication of any immediate medical attention and special treatment needed
Treatment :
Treat symptomatically.
For specialist advice physicians should contact the Poisons
Information Service.
SECTION 5: Firefighting measures
5.1 Extinguishing media
Suitable extinguishing media :
Dry extinguishing media based on NaCl or pulverized lime-
stone.
Unsuitable extinguishing
media
:
Water
Carbon dioxide (CO2)
Foam
5.2 Special hazards arising from the substance or mixture
Specific hazards during fire-
fighting
:
Dust can form an explosive mixture in air.
In contact with water releases flammable gases which may
ignite spontaneously.
Hazardous decomposition products formed under fire condi-
tions.
Hydrogen
Calcium oxide
5.3 Advice for firefighters
Special protective equipment
for firefighters
:
Wear full protective clothing and self-contained breathing ap-
paratus.