Installation and Operating Instructions 5
ABS lifting station PiranhamatABS lifting station Piranhamat
1.2.2 Nameplate
Legend
1114-00
Type Pump type
Nr./SN Item No./Serial No.
xx/xxxx Production date (Week/Year)
UN Rated Voltage V
IN Rated Current A
Frequency Hz
P1N Rated Input Power kW
n Speed min-1
Qmax Max. Flow m3/h
Hmax Max. Head m
IP 44 Protection type
Figure 3 Nameplate
1.3 Commentary on the legal regulations DIN and EN covering the use of lifting stations
for the pumping of sewage containing faecal matter
Automatic lifting stations are required if the normal water level in the odor lock of the efuent source lies under
the sewer backwash level.
In the case of installations of this size and design of the Piranhamat 100/120, only a single WC, one wash-hand
basin, one bidet and one shower tray may be connected. The direct or indirect connection of other efuent
sources is not allowed. In addition another WC must be available above the sewer backwash level. If more
efuent sources are present then we recommend our series Sanimat.
ATTENTION The regulations of DIN 1986/100 EN 12050 and 12056 should be observed!
1.4 Accessories
The Piranhamat 100/120 lifting unit is supplied as standard with the following ttings:
Non-return valve (ap type)
Hose clamp (x2)
Rubber cap
Fixing screw (x2)
Dowel oor xing (x2)
Ground xing (2)
* The version with part No. 07560320/07565092 has an additional seal with built-in non-return valve.
2 Transport
m
During transport the unit should not be dropped or thrown.
c
The unit should never be raised or lowered by the Power cable.
All relevant safety regulators as well as general good technical practice must be complied with.
-
-
-
-
-
-
-