Page 15AN120076.000_EN
Para-
meter
Range Unit Designation Remarks
P5.0 300 ms Extend measurement time (main lift only) Code
May only be changed with
the permission of ABUS
P5.01 20 – 255 Sensitivity to rapid load increase Code
May only be changed with
the permission of ABUS
P5.1 h Display of theoretical service life
P5.2 h Read load population recorder
P5.3 Acceptance test
P5.4 12 – 30 Set / chan ge inching counter
May only be changed with
the permission of ABUS
P5.5 Delete all settings
P6.1 Display / input Starting value for load population recorder
P6.2 h Display Actual hours of use S
P6.3 h Display Total operating hours Ti
P6.4 h Set FEM group
Special ABUS CODE
This parameter is used to
enable the load population
recorder;
The parameter can only be
set by ABUS.
P6.5 delete load population recorder Code
CODE only accessible to
inspector.
P7.0 Password input for level 3 Only for ABUS
P9.9 Quit parameter level
Quit menu level
11 Description of LIS – SE parameters
0015 Operating hours are displayed on unit.
This display appears if
1. after the hoist has been shut down for about 3 sec.
2. after you have pressed the ”Enter” button briefly
Menu level 1
CodE
Readout of load population re-
corder by customer:
Appears on the display if you press the Enter key for
some time, provided that the load population recorder
has been enabled by ABUS.
Menu level 2
Before carrying out any s ettings on the LIS–
SE, you should read the notes on the para-
meters carefully.
Always remember that incorrect settings may
cause malfunction.
ABUS will assume no liability whatsoever for
any damage to the crane or a ny consequen-
tial damage resulting from incorrect settings.
On level 2, if no entries are made for 5 minutes, the unit
switches to the operating mode.
All entries made and saved up to that point are maintai-
ned.
Parameter: P0.0
Total load capacity of crane or sy-
stem
Adjustment:
This parameter currently has no effect on evaluation. It
is not necessary to enter a value.