EasyManua.ls Logo

Abus LIS-SE - Page 30

Abus LIS-SE
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 30 Date: 01.03.2016
Voltage range 3
(220 240 V; 50 Hz. // 255 280 V; 60 Hz.)
Hoist motor Current measuing module
No.
Hoist
Type
Motor
Type
(Input
P1.1)
P
[KW]
at 50 Hz.
12 / 2 pole
In
[A]
12 / 2 pole
R I nput for
P1.2 (in Ohms)
12/2–pole
Measu-
ring
range
In
[A]
Current
measuing
module
Correction
factor
AN Remarks
13 GM 5000 H.3
0
2,9 / 18,8 21,1 / 59 1,31 / 0,09
V
60
2344
9747
14 GM 6000 L 3
0
2,9 / 18,8 21,1 / 59 1,31 / 0,09
V
60
2344
9747
15 Reserve
16 GM 7000 L
0
2,4 / 16 19,1 / 51 1,49 / 0,141
V
60
2344
9747 1 motor
17 GM 7000 H
0
4,8 / 32 38,2 / 102 0,745 / 0,07
VI
136
5169
19682 2 motors
18 GM 7000 M
0
3/20 23,4 / 69 1,31 / 0,09
VI
136
5169
19682 1 motor
19 GM 7000 U
0
6/40 46,8 / 138 0,44 / 0,045
VI
136
5169
19682 2 motors
20
R measured 3*Rmeasured [U–V] R measured
R Input = ––––––––––––– R phase = –––––––––––––––––– for 2 motors R Input = –––––––––––
22 4