BUFFER VPD SETTING
The buffer figure will create a trigger-off point
below your set trigger point to prevent your
device from shutting off too quickly. Press
the up or down button to cycle through buffer
range from 0.1 kPa and 1.0 kPa.
In high VPD triggers, your device will turn on,
only turning off when the VPD falls below your
buffer setting.
In low VPD triggers, your device will turn on,
only turning off when the VPD rises above your
set buffer setting.
EXAMPLE
In this example, your High VPD Trigger is set
at 2.51 kPa and your VPD Buffer is set at 0.2
kPa. Your device will trigger on when it meets
or rises above 2.51 kPa, and only trigger off
when it falls below 2.31 kPa%. The 2.51 kPa
figure is obtained by taking your High VPD
Trigger of 2.51% and subtracting your VPD
Buffer of 0.2 kPa.
BUFF.
2.51
kPa
2.31
kPa
0.2
kPa
PROGRAMMING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AC Infinity CONTROLLER 69 PRO and is the answer not in the manual?

AC Infinity CONTROLLER 69 PRO Specifications

General IconGeneral
ConnectivityWi-Fi, Bluetooth
Power SupplyAC Adapter
CompatibilityAC Infinity Devices
Operating Voltage5V DC
Amperage2A
Sensor Ports4
Fan Ports4
Control Ports4
Weight0.5 lbs
DisplayLCD
ControlManual Control
App CompatibilityiOS and Android

Related product manuals