User's Manual | ACOM 1200S | 1.8-54 MHz Linear Power Amplifier
Page
14
of
60
| S e c t i o n INSTALLATION
August 2021
2. INSTALLATION
2.1. Unpacking and Initial Inspection
Before you install your amplifier, thoroughly read this manual.
First, carefully inspect the cardboard carton and its contents for physical damage.
ACOM ships amplifiers in highly protected containers, but it cannot assure that
mistreatment by shippers will not occur. If damage is evident, notify your dealer
immediately. Delay may void the carrier's warranty.
Keep all packing materials for possible future amplifier shipment (see Section 8.3.4 Returning to the Service
Provider).
2.2. Line Voltage Selection
The ACOM 1200S amplifier is supplied with built-in switching-mode power supply (SMPS).
The amplifier operates in an extended mains voltage range of 100-240 VAC (output power reduced to
about 500 W PEP below 200 VAC), with no internal switch over. The consumed current is purely sinusoidal,
Power Factor Corrected (PFC) and inrush limited. This makes the operation from unstable mains and
generators easy and trouble free.
Thanks to the built-in SMPS, the ACOM 1200S has no mains line voltage selector to take
care of!