Heat pumps AIR / WATER
Operation manual 9
Heating capacity A7/W55 [kW]
3.87
7.41
COP A7/W55 [1]
3.28
3.29
Table 3 Performance parameters of nominal conditions EN 14 511
Model
PRO-N
PRO-R
Heating capacity A12/W27 [kW]
1.81
4.05
COP A12/W27 [1]
6.27
7.11
Heating capacity A7/W27 [kW]
1.63
3.81
COP A7/W27 [1]
5.55
6.33
Heating capacity A2/W30 [kW]
2.54
5.46
COP A2/W30 [1]
4.94
5.03
Heating capacity A-7/W34 [kW]
4.17
9.23
COP A-7/W34 [1]
3.14
3.24
Heating capacity A12/W34,8 [kW]
1.76
3.88
COP A12/W34,8 [1]
5.36
5.92
Heating capacity A7/W36 [kW]
1.60
3.52
COP A7/W36 [1]
4.41
4.97
Heating capacity A2/W42 [kW]
2.48
5.53
COP A2/W42 [1]
3.74
3.87
Heating capacity A-7/W52 [kW]
4.08
9
COP A-7/W52 [1]
2.38
2.5
SCOP W35 [1]
4.74
5.05
SCOP W55 [1]
3.68
3.93
Table 4 Performance parameters, equithermal regulation
Model
PRO-N
PRO-R
A7/W35
Fan speed [1/min]
320
337
Water flow [m
3
/h]
0.58
1.19
Pressure difference [kPa]
-2.93
-3.83
A2/W35
Fan speed [1/min]
320
337
Water flow [m
3
/h]
0.48
0.99
Pressure difference [kPa]
-2.07
-2.7
A7/W55
Fan speed [1/min]
320
337