Heat pumps AIR / WATER
Operation manual 36
Restart heat pump If the
fault occurs again, call
service
LOW FLOW
THROUGH PLATE
EXCHANGER
Clogged water filter
Aired water circuit
Insufficient performance, circulator
failure
Clean the water filter
Ventilate the water circuit
LOW FLOW
THROUGH
SOLUTION
EXCHANGER
Solution aerated circuit
Insufficient performance, solution
circulation pump failure
Ventilate solution circuit
HIGH TEMP OF
PLATE HEAT
EXCHANGER
Overheated by solar heating,
bivalent source (e.g. solid fuel boiler)
Only notice, will self-
resolve
Only notice, will self-
resolve
On arrival, when using another heat
source (e.g. boiler), at higher
outdoor temperature
Warning only, starts the
heat pump, disappears
on its own
LOW
TEMPERATURE
IN ROOM 2
Only notice, will self-
resolve
HIGH
TEMPERATURE
IN ACCU.
Overheated by solar heating,
bivalent source (e.g. solid fuel boiler)
Only notice, will self-
resolve
LOW
TEMPERATURE
OF EVAPORATOR
Low outdoor temperature, high
humidity
Warning only, triggers
defrost, extinguishes
itself
Only notice, will self-
resolve
Insufficient service water plate heat
exchanger flow, insufficient service
water circulation pump power, three-
way service water valve failure
Check primary circuit
throughput
Internet connection problem
If it lasts longer than 1
day, contact the service
ā see Chapter 0