12
Running relay terminal
No Symbol Terminal name Description
1 MA Running signal A Running contact (normal open)
2 CF3
Running signal B / multi-
function terminal
Running contact (normal close) / 5-8th
speed terminal
3 MC Running signal C Running contact (common)
Alarm terminal
No Symbol Terminal name Description
4 A/B Alarm output B
Fault alarm contact A(normal open) /
B(normal close)
5 C Alarm output C Fault alarm contact (common)
Multi function analog terminal
No Symbol Terminal name Description
6 VCC Analog source Power source +10V of analog terminals
7 FA1 Free analog terminal 1 See CD44 & jumper setup J7
8 GND Analog common terminal Common terminal of free analog terminals
Control circuit terminal
No Symbol Terminal name Description
9 FWD Forward operation Forward operation / stop terminal
10 REV Reverse operation Reverse operation / stop terminal
11 FT1 Multi function terminal 1 See functions description (CD42)
12 FT2 Multi function terminal 2 See functions description (CD43)
13 MT
Multi function output
terminal
Open collector output 50mA MAX
RUN : Operating indicator, refer to CD46
description
MET : Connect to frequency meter, refer
to CD07 description
ARR : Frequency arrived indicator, refer to
CD55 description
14 COM Common terminal Common terminal of control terminals
15 FG Ground(Earth) terminal